TCI TRADING CO. LTD.

CÔNG TY TNHH TƯ VẤN TÍCH HỢP CÔNG NGHỆ VÀ THƯƠNG MẠI

Welcome Visitor you can Login / Register
 
Filler

Remote General Purpose Interfaces

  • Provide simple contact closure inputs and outputs
  • Contact closure inputs select router inputs
  • Contact closure outputs tally router status
  • Single Bus or X-Y Control (X-Y control GPI-40 only)
  • Configurable for Joystick Override
So sánh sản phẩm
Chia sẻ nội dung

Contact Closure Interfaces

The RCP-GPI32p and RCP-GPI64p provide input and output contact closure interfaces for use with Imagine Communications routers. These devices allow interfacing of routers with external devices by providing the most basic of interface mechanisms, a contact closure. The three models vary in the number of contact closures, in their physical construction and in the capabilities that they provide.

The GPI inputs can be used to select router crosspoints. A source will be selected whenever the corresponding GPI input pair is shorted momentarily.

Detail

When GPI inputs are being used to control a single destination of a routing switcher, it is possible to configure the GPI inputs to behave in Joystick Override mode. In this mode the crosspoint is selected by shorting the appropriate contact pair. The crosspoint is held until the contact is released. At which point, the crosspoint returns to the last selection made from a control panel or by the serial port. This configuration is often used in camera applications to allow the camera operator to momentarily override router selections.

As with all other members in the Programmable Panel series these units can be easily programmed using the RouterMAPPER® utility included with the units. The mapping is very flexible allowing any GPI input and output to perform any function. This feature makes these units very powerful and flexible.

RCP-GPI32p
The RCP-GPI32p is an external (remote) interface which provides 32 input and output contacts. It can be configured to control and or tally a single destination within a router. The first 32 contacts control 32 consecutive sources (32×1 control). The remaining four contacts may be used as bank selects extending the capability of the RCP-GPI32p to select and tally up to 64 inputs (64×1 control).

RCP-GPI64p
The RCP-GPI64p is an external (remote) interface which provides 64 input and output contacts. The RCP GPI64p is capable of both single destination and X-Y control. In single destination configuration the RCP GPI64p can control up to 64 consecutive sources (64×1). In X-Y configuration the RCP-GPI64p can be used to select both sources and destinations allowing it to control the full matrix rather than a single destination. The RCP-GPI64p controls matrices of 16×16 up to 64×64.